Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Circ Cardiovasc Interv ; 14(5): e010288, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-34003666

RESUMO

BACKGROUND: The use of valve-in-valve­transcatheter aortic valve replacement (VIV-TAVR) in degenerated aortic bioprosthesis has been increasing, but the Food and Drug Administration approval is limited to high-risk patients. We analyzed the real-world experience of SAPIEN 3 VIV-TAVR, especially in lower-risk patients, based on the Society of Thoracic Surgeons (STS) score. METHODS: All transfemoral VIV-TAVR with the SAPIEN 3 and Ultra valves between June 2015 and January 2020 were identified using the STS/American College of Cardiology Transcatheter Valve Therapies Registry. Patients were grouped based on STS score (low score: <4%, intermediate score: 4%≤ and≤8%, high score: >8%). Propensity-matched (1:3) analysis was conducted to compare to patients undergoing native TAVR. RESULTS: Of 145 917 SAPIEN 3 TAVR patients, 4460 (3%) underwent transfemoral VIV-TAVR with available baseline STS data in 4276 patients. Average age was 73.9±11.2, 66.4% were male, and the mean STS score was 6.9±6.0%. Overall 30-day mortality was 2.4% (observed to expected ratio, 0.33), and 1-year mortality was 10.8%. 30-day mortality and observed to expected ratio were 0.9% and 0.32 in low-score, 2.2% and 0.38 in the intermediate-score, and 4.3% and 0.31 in the high-score group. Based on propensity-matched analysis, 30-day mortality was similar and 1-year mortality was lower in VIV compared to native TAVR among all risk groups. When the groups were analyzed based on the Heart Team risk stratification using high-risk and non­high risk, the findings remained consistent. CONCLUSIONS: In this real-world study, VIV-TAVR had excellent 30-day and 1-year outcomes, especially in lower-risk patients. These findings may suggest the feasibility and expansion of VIV-TAVR in lower-risk patients. However, long-term follow-up continues to be crucial.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Cirurgiões , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...